Electrical & Physical Specification

1 1000 MEGA OHM-KM Min. 1000 MEGA OHM-KM Min.
2 Conductor Resistance 1400 OHM/KM/20°C Max.
3 Dielectric Strength AC 1.0 KV/minute
4 Spark test 2.5 KV
5 Nom. Impedance 50 ± 3 Ohms
6 Nom. Capacitance 97 ± 3 pF/m
7 Attenuation (dB/1M) 2.0GHz 3.60
2.4GHz 5.10
3.0GHz 6.20
4.0GHz 7.50
5.0GHz 8.50
6.0GHz 9.40

Electrical & Physical Specification

Conductor Insulation Braid Shied Jacket
Material: Silver Plated Copper Material: FEP Material: Silver Plated Copper Material: PFA
32AWG(7/0.050mm) Avg. Thickness: 0.13mm Structure: 16/3/0.050mm± 0.003 Avg. Thickness: 0.09mm
Diameter: 0.15mm Diameter: 0.41±0.03mm Color: Natural Coverage: 90% Diameter: 0.63±0.02mm Diameter: 0.81±0.05mm Color: upon request

Technical Drawing

NoNameDesignationEmail
NO. Name PN Material Finish QTY
1 SMA(F) ST SMA.F.ST.JACK.B.W Brass Gold 1
2 0.81 Cable OD.081.W FEP Gray 1
3 Heat Shrink Tube 001312E000014A PE Black 1
4 IPEX MHF4 IPEX.MHF4.081 Brass Gold 1
5 Washer See Connector Spec Brass Gold 1

Connectors

Cable Insertion Loss

(1) Do not apply excess mechanical stress to the component body or terminations. Do not attempt to re-form or bend the components as this will
cause damage to the component.
(2) Do not expose the component to open flame.
(3) This specification applies to the functionality of the component as a single unit. Please ensure the component is thoroughly evaluated in the
application circuit.

You can also reach us on (+1) 212-946-2707 or (+1)212-946-2700 or  info@miotsolutions.com
our sale department will reply within 48 hours

You can also reach us on (+1) 212-946-2707 or (+1)212-946-2700 or  info@miotsolutions.com
our sale department will reply within 48 hours